Specifications
The tables below show detailed specifications of the TP508.
Acquisition system | |
---|---|
Number of input channels | 2 analog, BNC |
Resolution | 8 bit = 0.39% |
Accuracy | 2% of full scale ± 1 LSB |
Ranges | 20 mV to 80 V full scale |
Coupling | AC/DC |
Impedance | 1 MOhm / 20 pF |
Protection | 200 V (DC + AC peak < 10 kHz) |
Bandwidth (-3dB) | DC to 25 MHz |
AC coupling cut off frequency (-3dB) | ±1.5 Hz |
Maximum sampling rate | 50 MHz, 20 ns on one channel 25 MHz, 40 ns on two channels |
Sampling clock source | internal ±0.01%, external |
Memory | 32760 samples each channel |
Square Wave Generator (independent from acquisition system) | |
Number of output channels | 1 analog, BNC |
Waveforms | square |
Amplitude | -2 V to 2 V |
Impedance | 400 Ohm |
Frequency range | 100 Hz to 100 kHz |
Trigger system | |
System | hardware, 2 levels |
Source | CH1, CH2, AND, OR, digital external |
Trigger modes | rising edge, falling edge, inside window, outside window |
Level adjustment | 0 to 100% of full scale |
Hysteresis adjustment | 0 to 100% of full scale |
Resolution | 0.39% (8 bits) |
Digital trigger input level | 0 to 5 V max |
Pre trigger | 0 to 32760 samples (0 to 100%) |
Post trigger | 0 to 32760 samples (0 to 100%) |
Interface | |
Interface | 8 bit ISA slot |
Power Requirements | |
Power from ISA slot | +5 V : 800 mA +12 V : 250 mA -12 V : 100 mA |
Physical | |
Instrument height | 140 mm (5.5 inch) |
Instrument length | 245 mm (9.6 inch) |
Instrument width | 20 mm (0,8 inch) |
Weight | 250 g (8.8 ounce) |
Accessories | 2 oscilloscope probes 1:1-1:10 switchable bracket with D-sub connector |
Downloads
Download software, drivers, manuals and source code for the TP508.
Software & Driver
Description | Version | Remarks | Size | |
---|---|---|---|---|
LPT/ISA Driver (GiveIO.sys) | Windows NT4 / 2000 / XP, 32 bit | 247.57 kB | download | |
TP508 WinSoft measurement software (32 bit) | 2.87 | Windows 95/98/ME/NT4/2000/XP | 1.94 MB | download |
TP508 WinSoft measurement software (16 bit) | 2.30 | Windows 3.xx | 2.17 MB | download |
TP508 DOS Measurement software | 1.0 | DOS protected mode, Dutch | 265.75 kB | download |
TP508 DOS Measurement software | 1.0 | DOS protected mode, English | 265.73 kB | download |
Manuals
Programming
Description | Version | Remarks | Size | |
---|---|---|---|---|
TP508 Instrument DLL (32 bit) | 2.90 | Windows 95/98/ME/NT4/2000/XP | 454.53 kB | download |
TP508 Instrument DLL (16 bit) | Windows 3.xx | 104.79 kB | download | |
Borland C++ Builder example | 18.53 kB | download | ||
Borland Delphi example | 15.38 kB | download | ||
DOS source code archive | Basic / C / Pascal | 179.18 kB | download | |
DasyLab driver | For all TiePie measuring instruments | 259.46 kB | download | |
Instrument DLL programmer's manual | 1.29 | English | 331.35 kB | download |
Matlab example | for Matlab 6.5.1 and higher | 2.80 kB | download | |
Python binding for instrument DLL | 1.7 | for Python 2.7 (Windows 32 bit) | 200.51 kB | download |
Python examples | 1.7 | 4.90 kB | download | |
Visual Basic 6 example | 12.84 kB | download |