The TP801 AWG PCI is no longer manufactured and sold.
For an overview of all oscilloscopes, visit the Oscilloscopes page.
Software will remain available through this web site, but it will no longer be updated.
Specifications
The tables below show detailed specifications of the TP801 AWG PCI.
Acquisition system | |
---|---|
Number of input channels | 2 analog |
Resolution | 8 bit = 0.39% |
Accuracy | 1% of full scale ± 1 LSB |
Ranges | 100 mV to 80 V full scale |
Coupling | AC/DC |
Impedance | 1 MOhm / 30 pF |
Protection (in all ranges) | 200 V (DC + AC peak < 10 kHz) |
Bandwidth (-3dB) | DC to 50 MHz |
AC coupling cut off frequency (-3dB) | ±1.5 Hz |
Maximum sampling rate | 100 MHz, 10 ns on one channel 50 MHz, 20 ns on two channels |
Sampling clock source | internal, ±0.01%, external |
Memory | 65536 samples each channel |
Arbitrary Waveform Generator (independent from acquisition system) | |
Number of output channels | 1 analog, BNC |
Resolution | 10 bit |
Amplitude | -10 V to 10 V |
Amplitude step | 0 to 0.1 V range, 4096 steps 0.0 to 0.9 V range, 4096 steps 0.9 to 10 V range, 4096 steps |
Coupling | DC |
Impedance | 50 Ohm |
Bandwidth | DC to 2 MHz |
DC level | 0 to 10 V in 4096 steps |
Sample rate | 0 to 25 MHz |
Sampling source | internal ±0.01% |
Memory depth | 1024 points DDS mode 65535 points linear mode |
Waveforms | sine, triangle, square, DC, noise and user defined |
Symmetry | 1 to 99%, 1% steps |
Trigger system | |
System | hardware, 2 levels |
Source | CH1, CH2, AND, OR, digital external |
Trigger modes | rising edge, falling edge, inside window, outside window, peak, TV line, TV frame |
Level adjustment | 0 to 100% of full scale |
Hysteresis adjustment | 0 to 100% of full scale |
Resolution | 0.39% (8 bits) |
Digital external trigger input level | TTL (0V to 5V) |
Pre trigger | 0 to 65520 samples (0 to 100%) |
Post trigger | 0 to 65520 samples (0 to 100%) |
Interface | |
Interface | PCI slot |
Power Requirements | |
Power from PCI slot | 3.5 W max |
Physical | |
Instrument height | 126 mm (5.0 inch) |
Instrument length | 200 mm (7.9 inch) |
Instrument width | 22 mm (0.9 inch) |
Weight | 166 g (5.9 ounce) |
Accessories | 2 oscilloscope probes 1:1-1:10 switchable bracket with D-sub connector |
Downloads
Download the software, drivers, manuals and source code for the TP801 AWG PCI.
Software & Driver
Manuals & Documents
Programming
Description | Version | Remarks | Size | |
---|---|---|---|---|
TP801 PCI Instrument DLL (32 bit) | 2.90 | Windows 95/98/ME/NT4/2000/XP | 460.20 kB | download |
Borland C++ Builder example | 18.53 kB | download | ||
Borland Delphi example | 15.38 kB | download | ||
DasyLab driver | For all TiePie measuring instruments | 259.46 kB | download | |
Instrument DLL programmer's manual | 1.29 | English | 331.35 kB | download |
Matlab example | for Matlab 6.5.1 and higher | 2.80 kB | download | |
Python binding for instrument DLL | 1.7 | for Python 2.7 (Windows 32 bit) | 200.51 kB | download |
Python examples | 1.7 | 4.90 kB | download | |
Visual Basic 6 example | 12.84 kB | download |