TiePieSCOPE HS805

Warning:
The TiePieSCOPE HS805 is no longer manufactured and sold.
For an overview of all oscilloscopes, visit the Oscilloscopes page.

TiePieSCOPE HS805: 2 channel high speed USB oscilloscope with Arbitrary Waveform Generator

Software will remain available through this web site, but it will no longer be updated.

Specifications

The tables below show detailed specifications of the TiePieSCOPE HS805. Jump to acquisition specifications, function generator specifications or general specifications.

Acquisition system

Number of input channels2 analog
CH1, CH2BNC
TypeSingle ended
Resolution8 bits
Amplitude accuracy1 % of full scale
Offset accuracy1 % of full scale
Ranges200 mV to 80 V full scale in a 2 - 4 - 8 sequence
CouplingAC/DC
Impedance1 MOhm // 20 pF
Maximum input voltage (in all ranges)200 V (DC + AC peak < 10 kHz)
Maximum input voltage with 1:10 probe (in all ranges)600 V (DC + AC peak < 10 kHz)
Bandwidth (-3dB)250 MHz
AC coupling cut off frequency (-3dB)1.5 Hz
Rise time1.5 ns
Overshoot1 %
Maximum sampling rate1 GSa/s (one channel)
500 MSa/s (two channels)
Sampling clock sourceinternal, external
Internalquartz
Accuracy±0.01 %
Stability±100 ppm over -40°C to +85°C
ExternalLVDS, on extension connector
Memory32 Mpts per channel
Trigger 
Systemdigital, 2 levels
SourceCH1, CH2, AND, OR,
Analog external, Digital external
Trigger modesrising edge, falling edge
Level adjustment0 to 100 % of full scale
Hysteresis adjustment0 to 100 % of full scale
Resolution0.39 % (8 bits)
Pre trigger0 to 32 MiSamples (0 to 100 %, 1 sample resolution)
Post trigger0 to 32 MiSamples (0 to 100 %, 1 sample resolution)
Analog external trigger 
InputBNC
Range200 mV to 80 V full scale
CouplingAC/DC
Bandwidth20 MHz
Maximum input voltage (in all ranges)200 V (DC + AC peak < 10 kHz)
Digital external trigger 
Inputextension connector
Range0 to 5 V (TTL)
CouplingDC

Arbitrary Waveform Generator (independent from acquisition system)

WaveformsSine, Square, Triangle, DC, Noise, Arbitrary
Output channel1 analog, BNC
DAC resolution14 bits @ 200 MHz
Output range-12 to +12 V
Amplitude 
Range0 to 0.12 V, 0.12 to 1.2 V, 1.2 to 12 V
Resolution12 bit
DC offset 
Range-12 to 12 V
Resolution12 bit
CouplingDC
Impedance50 Ohm
BandwidthDC to 20 MHz
  
System characteristics 
SystemDDS
Memory32 MiSamples
Maximum sampling rate200 MHz
Sampling clock sourceinternal, 0.01 %
Accuracy±0.01 %
Stability±100 ppm over -40 °C to +85 °C

Interface

InterfaceUSB 2.0 High Speed (480 Mbit/s)
(USB 1.1 Full Speed (12 Mbit/s) and USB 3.0 compatible)

Power Requirements

Power adapterExternal
Input110 to 240 VAC, 50 to 60 Hz
0.85 A Max., 50 VA to 80 VA
Output5 VDC, 1.5 A
12 VDC, 1.5 A
Dimension33 x 58 x 102 mm / 1.3 x 2.3 x 4 inch (h x w x l)
Consumption5 VDC, 1500 mA max
12 VDC, 1500 mA max

Physical

Instrument height57 mm (2.3 inch)
Instrument length276 mm (10.9 inch)
Instrument width180 mm (7.1 inch)
Weight1250 g (2.8 lbs)
USB cable length1.2 m (47 inch)
Power cord length1.5 m (59 inch)

I/O connectors

Ch1, Ch2BNC
Generator outBNC
Analog external trigger inputBNC
Power5 pin Mini-DIN socket
USBtype B socket
Extension connectorD-Sub 15 pins female

System Requirements

PC I/O connectionUSB 2.0 High Speed (480 Mbit/s)
(USB 1.1 Full Speed (12 Mbit/s) and USB 3.0 compatible)
Operating SystemWindows 98/ME/2000/XP/Vista/7/8/10

Operating Environment

Ambient temperature0 to 55 °C
Relative humidity10 to 90 % non condensing

Storage Environment

Ambient temperature-20 to 70 °C
Relative humidity5 to 95 % non condensing

Certifications and Compliances

CE mark complianceYes
RoHSYes

Package

InstrumentTiePieSCOPE HS805
Oscilloscope probes2 x Oscilloscope Probe 1:1-1:10 - HP-9250
SoftwareWindows 98/2000/ME/XP/Vista/7/8/10
DriversWindows 98/2000/ME/XP/Vista/7/8/10
Manualinstrument manual and software user manuals
color printed on paper and digital

Downloads

Downloads for the TiePieSCOPE HS805 are listed below.

Driver & Software

DescriptionVersionRemarksSize
TiepieSCOPE HS805 USB driver6.0.7.0Windows 98 / ME / 2000 / XP / Vista / 7 / 8, 32 and 64 bit496.68 kB download
Final Multi Channel software for TiePieSCOPE HS8051.33.2Windows XP / Vista / 7 / 8 / 10, 32 bit,
for instrument USB driver 6.0.7 / 6.0.8 / 6.1.3
26.68 MB download

Manuals & Documents

DescriptionVersionRemarksSize
Multi Channel software manual 1.11English3.13 MB download
TiePieSCOPE HS805 Instrument manual2.16English1.49 MB download
TiePieSCOPE HS805 data sheetEnglish1.55 MB download

Programming

DescriptionVersionRemarksSize
TiePieSCOPE HS805 Instrument DLL (32 bit)1.30.0For 32 bit applications on Windows 98/ME/2000/XP/Vista/7/8/10 (32/64 bit)1.06 MB download
TiePieSCOPE HS805 Instrument DLL (64 bit)1.30.0For 64 bit applications on Windows XP/Vista/7/8/10 (64 bit)2.07 MB download
Borland C++ Builder example18.53 kB download
Borland Delphi example15.38 kB download
DasyLab driverFor all TiePie measuring instruments259.46 kB download
Instrument DLL programmer's manual1.29English331.35 kB download
Matlab examplefor Matlab 6.5.1 and higher2.80 kB download
Matlab streaming examplefor Matlab 6.5.1 and higher with callback adapter7.11 kB download
Python binding for instrument DLL1.7for Python 2.7 (Windows 32 bit)200.51 kB download
Python binding for instrument DLL1.7for Python 2.7 (Windows 64 bit)228.16 kB download
Python examples1.74.90 kB download
Visual Basic 6 example12.84 kB download