4 channel high resolution PC oscilloscope
Base price: € 769.00
Measure 4 channels simultaneously
Key specifications
- 12, 14, 16 bit resolution, 0.2 % DC vertical accuracy
- Up to 50 MSa/s sampling, 50 MHz bandwidth
- 128 KSamples memory per channel
Full specifications Data sheet Manual Request info
- Handyscope HS4-50
- Handyscope HS4-25
- Handyscope HS4-10
- Handyscope HS4-5
- Five year warranty (W5)
Order code:
EAN:
Price:
This professional powerful computer controlled USB oscilloscope features four input channels. The Handyscope HS4 oscilloscope features a user selectable 12 bit, 14 bit or 16 bit resolution (14 bit effective, SNR 95 dB), 200 mV to 80 V full scale input range and 128 Ksamples record length per channel. Four Handyscope HS4 oscilloscope models are available, with a maximum sampling rate of respectively 5 MSa/s, 10 MSa/s, 25 MSa/s or 50 MSa/s on all four channels simultaneously.
Fast continuous streaming
Besides measuring in block mode as oscilloscope, the Handyscope HS4 is also capable of performing continuous streaming measurements as data logger. This will create a continuous uninterrupted data stream to the computer. The data can then be displayed on the screen and/or saved to disk.
Combining multiple Handyscope HS4s
When one Handyscope HS4 does not offer enough input channels, the Handyscope HS4 can be coupled to one or more other instruments. This allows to make a combined instrument which will enable simultaneous measuring on all channels of all combined instruments.
Versatile Multi Channel oscilloscope software
The Handyscope HS4 is delivered with the versatile Multi Channel oscilloscope software, which transforms the Handyscope HS4 into an oscilloscope, spectrum analyzer, data logger, multimeter and protocol analyzer.
Some of the powerful features of the Multi Channel oscilloscope software are indicated below, for a full description of the Multi Channel oscilloscope software, refer to the Multi Channel oscilloscope software pages.
Many automatic measurements
The Multi Channel oscilloscope software features many automatic measurements, that can be performed on the measured signals of your Handyscope or on a selection of the measured signals. Using the automatic measurements in the oscilloscope, any detail of your signal is revealed. Two sets of cursors, both horizontal and vertical, can be used to indicate a part of the signal that needs to be examined thoroughly. The automatic measurements include e.g.: Mininum, Maximum, Top-Bottom, RMS, Mean, Variance, Standard deviation, Frequency.
The measurement results are shown in a special value window that can be positioned anywhere on your computer screen. A convenient toolbar allows you to enable or disable a measurement with a single click. The measurement results can be copied to the clipboard e.g. to use them in reports. When printing the graphs, the cursors and measurements results are also included.
Analyze fast serial communication protocols
To analyze or debug your serial communications, simply measure the signal(s) transferring the protocol with your Handyscope and have them analyzed and decoded by one of the Multi Channel oscilloscope software protocol analyzers. The decoded information from the serial communications can be shown in tables, in graphs and in the multimeter.
A protocol analyzer is a useful tool when developing a hardware and/or software implementation of a communication bus. It can also be used when debugging device or bus failures.
Flexible signal displays
The Multi Channel oscilloscope software scope, spectrum analyzer and datalogger offer an ultimately flexible way to display all aspects of the measured signals. They can have one or more graphs, each displaying one or more signals, where each graph can display different parts of a signal. Graphs can display the signal(s) of your Handyscope in Yt mode, in XY mode or as frequency spectrum, with or without interpolation. Colors of all items in a graph can be set to any required value. Graph dimensions can be adjusted to any required size, graphs can be located in one single window or in separate windows, which can be located anywhere on the desktop.
24/7 Data logging
Measuring long term signal changes with your Handyscope is done with the Multi Channel oscilloscope software Data logger. The data logger logs your signal, continuously uninterrupted at high speed, 24 hour a day, 7 days a week. Results are immediately shown on the screen and all data can be stored to disk. A convenient toolbar lets you navigate through the stored files to find the important moments in the measurement.
More features
To discover more features of the comprehensive Multi Channel oscilloscope software for your Handyscope HS4, visit the Multi Channel oscilloscope software pages for a full description.
Handyscope HS4 specifications
The tables below show detailed specifications of the Handyscope HS4. Jump to specifications regarding
Acquisition system | ||||
---|---|---|---|---|
Number of input channels | 4 analog | |||
Ch1, CH2, CH3, CH4 | BNC, female | |||
Type | Single ended | |||
Resolution | User selectable in software | |||
Native | 12 bit | |||
Enhanced | 14, 16 bit | |||
Accuracy | 0.2 % of full scale ± 1 LSB | |||
Noise | 150 µVrms (200 mV range, 12 bit, 50 MSa/s) 450 µVrms (200 mV range, 16 bit, 195 kSa/s) | |||
Ranges (Full scale) | ±200 mV ±400 mV ±800 mV | ±2 V ±4 V ±8 V | ±20 V ±40 V ±80 V | |
Coupling | AC/DC | |||
Impedance | 1 MΩ / 30 pF | |||
Maximum input voltage (in all ranges) | ±200 V (DC + AC peak < 10 kHz) | |||
Maximum input voltage with 1:10 probe(in all ranges) | ±600 V (DC + AC peak < 10 kHz) | |||
Bandwidth (-3dB) | DC to 50 MHz maximum | |||
AC coupling cut off frequency (-3dB) | 1 Hz with 1x probe | |||
Maximum sampling rate | HS4-50 | HS4-25 | HS4-10 | HS4-5 |
12 bit | 50 MSa/s | 25 MSa/s | 10 MSa/s | 5 MSa/s |
14 bit | 3.125 MSa/s | 3.125 MSa/s | 3.125 MSa/s | 3.125 MSa/s |
16 bit | 195.3 kSa/s | 195.3 kSa/s | 195.3 kSa/s | 195.3 kSa/s |
Maximum streaming rate | HS4-50 | HS4-25 | HS4-10 | HS4-5 |
12 bit | 500 kSa/s | 250 kSa/s | 100 kSa/s | 50 kSa/s |
14 bit | 480.8 kSa/s | 250 kSa/s | 99.2 kSa/s | 50 kSa/s |
16 bit | 195.3 kSa/s | 195.3 kSa/s | 97.7 kSa/s | 48.8 kSa/s |
Sampling clock source | ||||
Internal | Quartz | |||
Accuracy | ±0.01 % | |||
Stability | ±100 ppm over -40 °C to +85 °C | |||
Time base aging | ±5 ppm/year | |||
External | On extension connector | |||
Voltage | 3.3 V TTL, 5 V TTL tolerant | |||
Frequency range | 95 MHz to 105 MHz | |||
Memory | 128 Kpts per channel | |||
Trigger | Only available in scope/block mode, not in streaming mode | |||
System | Digital, 2 levels | |||
Source | CH1, CH2, CH3, CH4, OR, digital external | |||
Trigger modes | Rising edge, Falling edge Inside window, Outside window | |||
Level adjustment | 0 to 100 % of full scale | |||
Hysteresis adjustment | 0 to 100 % of full scale | |||
Resolution | 0.025 % (12 bits) | |||
Pre trigger | 0 to 131071 samples, 1 sample resolution | |||
Post trigger | 0 to 131071 samples, 1 sample resolution | |||
Trigger hold-off | 0 to 1048576 Samples, 1 sample resolution | |||
Digital external trigger | ||||
Input | Extension connector | |||
Range | 0 to 3.3 V (5 V max) | |||
Coupling | DC | |||
Interface | ||||
Interface | USB 2.0 High Speed (480 Mbit/s); (USB 1.1 Full Speed (12 Mbit/s) and USB 3.0 compatible) | |||
Power Requirements | ||||
Power from USB port | 500 mA max (2.5 W max) | |||
Power via external power input / extension connector | 1500 mA max (7.5 W max) | |||
Minimum voltage | 4.5 VDC | |||
Maximum voltage | 12 VDC | |||
Physical | ||||
Instrument height | 25 mm (1 inch) | |||
Instrument length | 170 mm (6.7 inch) | |||
Instrument width | 140 mm (5.2 inch) | |||
Cord length | 1.8 m (70 inch) | |||
Weight | 480 g (17 ounce) | |||
I/O connectors | ||||
Channel 1...4 | BNC, female | |||
USB | fixed cable with USB 2.0 and USB 1.1 type A | |||
Extension connector | D-sub 25 pins female | |||
System Requirements | ||||
PC I/O connection | USB 2.0 High Speed (480 Mbit/s); (USB 1.1 Full Speed (12 Mbit/s) and USB 3.0 compatible) | |||
Operating System | Windows 10 / 11 and Linux (via libtiepie-hw SDK) | |||
Operating Environment | ||||
Ambient temperature | 0 to 55 °C | |||
Relative humidity | 10 to 90% non condensing | |||
Storage Environment | ||||
Ambient temperature | -20 to 70 °C | |||
Relative humidity | 5 to 95% non condensing | |||
Certifications and Compliances | ||||
CE mark compliance | yes | |||
RoHS | yes | |||
Package | ||||
Instrument | Handyscope HS4 | |||
Oscilloscope probes | 4 x Oscilloscope Probe 1:1-1:10 - HP-3250I | |||
Accessories | external power cable for second USB port | |||
Software | Windows 10 / 11, via website | |||
Drivers | Windows 10 / 11, via website | |||
Software Development Kit | for Windows 10 / 11 and Linux, via website | |||
Manuals | instrument manual and software user's manuals color printed on paper and digital, via website |
The Handyscope HS4 is available in 4 different models that distinguish in maximum sampling rate and maximum streaming rate:
Order code | Max. sampling speed | Max. streaming speed |
---|---|---|
HS4-50 | 50 MSa/s | 500 KSa/s |
HS4-25 | 25 MSa/s | 250 KSa/s |
HS4-10 | 10 MSa/s | 100 KSa/s |
HS4-5 | 5 MSa/s | 50 KSa/s |
Available options for the Handyscope HS4 are:
- W5: With the extended warranty option, warranty is five years on parts and labor. Without this option, the models have two years warranty on parts and labor.
The Handyscope HS4 is delivered with:
Instrument | Handyscope HS4 |
---|---|
Probe | 4x Oscilloscope Probe 1:1-1:10 - HP-3250I |
Accessories | external power cable for USB port |
Software | for Windows 10 / 11, via website |
Drivers | for Windows 10 / 11, via website |
Software Development Kit | for Windows 10 / 11 and Linux, via website |
Manuals | instrument manual and software user's manuals color printed and digital, via website |
Several downloads for the Handyscope HS4 are listed below, including Multi Channel oscilloscope software, drivers and manuals.
Driver & Software
Description | Version | Remarks | Size | |
---|---|---|---|---|
WinUSB driver | 10.0.2 | Windows 10 / 11, 64 bit | 1.73 MB | download |
Multi Channel software | 1.47.0 | Windows 10 / 11, 64 bit, including PDF manual | 103.76 MB | download |
Manuals & Documents
Description | Version | Remarks | Size | |
---|---|---|---|---|
Multi Channel software manual | 1.11 | English | 3.13 MB | download |
Handyscope HS4 Instrument manual | 2.49 | English | 379.90 kB | download |
Handyscope HS4 Brochure | English | 533.46 kB | download | |
Handyscope HS4 Data sheet | English | 1.38 MB | download |
Software Development Kit (SDK)
Interfacing the Handyscope HS4 with third party software and developing own software requires the libtiepie-hw Software Development Kit. Detailed information on the libtiepie-hw SDK, downloads for Windows and Linux platforms and bindings and programming examples for various programming environments can be found in the libtiepie-hw pages.