libtiepie-hw SDK changelog

This is a change log for the libtiepie-hw Software Development Kit.

Version 1.3.3

Version 1.3.0

Version 1.2.7

  • Fixed .NET deadlock on app exit, finalizers are not called on exit for .NET6 and higher
  • Added events to C# binding
  • Fixed tiepie_hw_object_is_removed
  • Improved Handyscope HS5 generator pulse period, calcPulseDataLength didn't always find the best record length due to rounding errors.

Version 1.2.6

Version 1.2.5

Version 1.2.4

  • Simplified tiepie_hw_oscilloscope_channel_trigger_set_level by using SetLastStatusByValue
  • Added TIEPIE_HW_STATUS_VALUE_MODIFIED to tiepie_hw_oscilloscope_channel_trigger_set_level

Version 1.2.3

  • Fixed usb hotplug detect

Version 1.2.2

Version 1.2.1

  • Updated libtiepie-nw to v0.16.9

Version 1.1.14

  • Improved tiepie_hw_devicelist_update, wait for servers to reach connected state

Version 1.1.13

  • Updated modules

Version 1.1.12

  • Added documentation for TIEPIE_HW_TC_INSIDE and TIEPIE_HW_TC_OUTSIDE

Version 1.1.11

  • Updated libtiepie-usb to v0.8.3

Version 1.1.10

  • Handyscope HS5 stream measuring did not start correct. There where additional samples before signal.
  • Updated TPFW to v2.2.36
  • Fixed trigger output delay samples

Version 1.1.9

  • BugFix: Apply trigger condition only on channel 1 for trigger types
    • TIEPIE_HW_TK_INWINDOW
    • TIEPIE_HW_TK_OUTWINDOW
    • TIEPIE_HW_TK_ENTERWINDOW
    • TIEPIE_HW_TK_EXITWINDOW