The USB oscilloscope packed with technology
Base price: € 1,290.00
The 1 GSa/s 14 bit quad channel High Resolution Oscilloscope.
Key specifications
- 8, 12, 14, 16 bit resolution, 0.25 % DC vertical accuracy, 0.1 % typical
- Up to 1 GSa/s sampling, up to 250 MHz bandwidth
- Up to 256 Mpoints memory per channel
- Up to 200 MSa/s continuous streaming
- 1 ppm time base accuracy
Full specifications Data sheet Manual Request info
- Handyscope HS6-1000
- Handyscope HS6-500
- Handyscope HS6-200
- Extended memory (XM)
- EMI (E)
- SureConnect (S)
- Five year warranty (W5)
Order code:
EAN:
Price:
This powerful USB 3.0 super speed oscilloscope combines fast sampling up to 1 GSa/s with high resolutions of 12, 14 and 16 bit and a large memory of 64 Mpoints on all four channels. The oscilloscope supports continuous streaming measurements up to 200 MSa/s and can be synchronized with other oscilloscopes using the CMI interface to form a multi channel combined instrument with synchronized time base. The CMI interface is available by default on the Handyscope HS6. Optionally, the Handyscope HS6 can be delivered with SureConnect connection test and resistance measurement on each channel.
SureConnect
While measuring, the revolutionary SureConnect connection test feature of the Handyscope HS6 checks in real time whether your test probe or clip actually makes electrical contact with your test subject.
EMI pre compliance testing
The powerful capabilities of the Handyscope HS6 - 1000XMES EMI analyzer give the user the possibility to quickly perform a good EMI compliance test. With this cost effective test, time and money are saved by avoiding extra visits to expensive EMC testing facilities. The supplied EMI probe set TP-EMI-HS6 contains three magnetic field (H field) probes and one electric field (E field) probe. The tripod ensures that the probes can be positioned properly at the object under test.
Multi oscilloscope synchronisation
The Handyscope HS6 is equipped with a sophisticated CMI synchronization bus, allowing to connect multiple Handyscope HS6s to each other by means of TP-C50H Coupling cable CMIs, to use them as a combined and synchronized oscilloscope. All Handyscopes will measure at the same sample frequency (0 ppm deviation!). Apart from a synchronization bus, the CMI also contains a trigger bus and a detection bus. The maximum number of Handyscopes is only limited by the number available USB ports.
Read more about CMI multi instrument synchronisation View the CMI interface video
When the instruments are located further apart, yet have to be combined and synchronized, the Wireless Multi Instrument Synchronization Module WCMI can be used. The WCMI modules are connected to the extension port of the instruments and allow to synchronize instruments that are up to 400 m apart.
High accuracy
The Handyscope HS6 measures with high resolutions of 14 and 16 bit. A signal measured with the Handyscope HS6 therefore has 256 times more resolution than most standalone oscilloscopes, which usually have a low resolution of 8 or 9 bit. The high resolution of the Handyscope HS6 precision oscilloscope allows for measuring signals with more accuracy, because the quantization error is much lower.
Large memory
When measuring at high sample rates, a long record length/large memory is necessary to be able to record a complete signal in the acquisition buffer. Where most oscilloscopes have 2.5 kpoints or 100 kpoints memory, the Handyscope HS6 has up to 256 Mpoints memory per channel, depending on the selected resolution and the number of active channels. When measuring at 14 bit resolution and all four channels, the available memory is 32 Mpoints per channel. This gives the user 300 to 100000 times more memory. An advantage of a large memory is that once-only fast phenomena can be captured accurately or complete serial communication signal blocks can be measured all at once. For example complete serial communications, like CAN bus signals, can be measured all in one record to be reviewed and analyzed afterwards.
Bandwidth limit
It seems reasonable to assume that more bandwidth is better, but a wider bandwidth gives more noise. To reduce your noise you can switch on a bandwidth limiter for each channel of the Handyscope HS6.
Versatile Multi Channel oscilloscope software
The Handyscope HS6 is delivered with the versatile Multi Channel oscilloscope software, which transforms the Handyscope HS6 into an oscilloscope, spectrum analyzer, data logger, multimeter and protocol analyzer.
Some of the powerful features of the Multi Channel oscilloscope software are indicated below, for a full description of the Multi Channel oscilloscope software, refer to the Multi Channel oscilloscope software pages.
Quick Setup
To simplify setting up the measurements, the Multi Channel oscilloscope software contains a large number of Quick Setups, for almost any application. A Quick Setup contains the basic settings for a specific measurement as well as additional information regarding the selected Quick Setup, like e.g. how your Handyscope and/or accessories need to be connected. Quick Setups can also contain reference signals. After loading the Quick Setup, that specific measurement can be performed and if needed, small adjustments to the setup can be made.
The Quick Setups are carefully organized in a tree structure, ordered by application. Just a few mouse clicks allow to perform a complex measurement.
Flexible signal displays
The Multi Channel oscilloscope software scope, spectrum analyzer and datalogger offer an ultimately flexible way to display all aspects of the measured signals. They can have one or more graphs, each displaying one or more signals, where each graph can display different parts of a signal. Graphs can display the signal(s) of your Handyscope in Yt mode, in XY mode or as frequency spectrum, with or without interpolation. Colors of all items in a graph can be set to any required value. Graph dimensions can be adjusted to any required size, graphs can be located in one single window or in separate windows, which can be located anywhere on the desktop.
Many automatic measurements
The Multi Channel oscilloscope software features many automatic measurements, that can be performed on the measured signals of your Handyscope or on a selection of the measured signals. Using the automatic measurements in the oscilloscope, any detail of your signal is revealed. Two sets of cursors, both horizontal and vertical, can be used to indicate a part of the signal that needs to be examined thoroughly. The automatic measurements include e.g.: Mininum, Maximum, Top-Bottom, RMS, Mean, Variance, Standard deviation, Frequency.
The measurement results are shown in a special value window that can be positioned anywhere on your computer screen. A convenient toolbar allows you to enable or disable a measurement with a single click. The measurement results can be copied to the clipboard e.g. to use them in reports. When printing the graphs, the cursors and measurements results are also included.
High detail spectrum analyzer
The high detail Multi Channel oscilloscope software spectrum analyzer takes full benefit of the deep memory of the high resolution USB Handyscopes. Not only gives the deep memory an incredible low resolution bandwidth of just 7.45 Hz at a frequency span of 500 MHz, it also gives a vertical dynamic range of 140 dB. The fast and powerful FFT routines with many user selectable window functions allow you to see the smallest frequency components in your signals.
The multi display option of the Multi Channel oscilloscope software spectrum analyzer allows viewing multiple parts of the spectrum at the same time, giving a better understanding of the signals that are analyzed.
Advanced triggers
To control the advanced trigger capabilities of your Handyscope, the Multi Channel oscilloscope software provides for a convenient trigger properties dialog. It allows to view and set all properties of the trigger, like e.g. trigger source, trigger type, all levels and hystereses and optional time conditions. Additionally, it gives an explanation on the selected trigger type and examples that do cause a trigger (left column) and do not cause a trigger (right column).
Unlimited zoom
When measuring at high sample rates, a long record length is a must, otherwise the acquisition buffer is full before the signal is measured. Therefore, our Handyscopes can have up to 256 MSamples record length per channel.
To view all that data conveniently and yet being able to see all details of the signals, the Multi Channel oscilloscope software scope, spectrum analyzer and data logger support sophisticated signal drawing routines with unlimited zooming capabilities. The full signal can be shown on any display size, without loss of information. Yet, you can zoom in to any required level, to see the finest details in the signals. Zooming factors of 1 million of even more are no problem, you can zoom in far beyond sample level.
Analyze fast serial communication protocols
To analyze or debug your serial communications, simply measure the signal(s) transferring the protocol with your Handyscope and have them analyzed and decoded by one of the Multi Channel oscilloscope software protocol analyzers. The decoded information from the serial communications can be shown in tables, in graphs and in the multimeter.
A protocol analyzer is a useful tool when developing a hardware and/or software implementation of a communication bus. It can also be used when debugging device or bus failures.
24/7 Data logging
Measuring long term signal changes with your Handyscope is done with the Multi Channel oscilloscope software Data logger. The data logger logs your signal, continuously uninterrupted at high speed, 24 hour a day, 7 days a week. Results are immediately shown on the screen and all data can be stored to disk. A convenient toolbar lets you navigate through the stored files to find the important moments in the measurement.
More features
To discover more features of the comprehensive Multi Channel oscilloscope software for your Handyscope HS6, visit the Multi Channel oscilloscope software pages for a full description.
Handyscope HS6 specifications
The tables below show detailed specifications of the Handyscope HS6. Jump to specifications regarding
Acquisition system | |||||
---|---|---|---|---|---|
Number of input channels | 4 analog | ||||
CH1, CH2, CH3, CH4 | Female BNC | ||||
Type | Single ended input | ||||
Resolution | User selectable in software | ||||
Native | 8, 12, 14 bit | ||||
Enhanced | 16 bit | ||||
DC Accuracy | 0.25 % (0.1 % typical) of full scale ± 1 LSB at 20°C to 25°C To achieve rated accuracy, allow the instrument to settle for 20 minutes. When subjected to extreme temperatures, allow additional time for internal temperatures to stabilize. | ||||
Noise | 240 µVrms (200 mV range, 12 bit, 50 MSa/s) 90 µVrms (200 mV range, 16 bit, 6.25 MSa/s) | ||||
Ranges (full scale) | ±200 mV ±400 mV ±800 mV | ±2 V ±4 V ±8 V | ±20 V ±40 V ±80 V | ||
Coupling | AC/DC | ||||
Impedance | 1 MΩ / 20 pF ± 1 % | ||||
Maximum voltage | 200 V (DC + AC peak < 10 kHz) | ||||
Bandwidth | HS6-1000 | HS6-500 | HS6-200 | ||
-3dB at 75 % of full scale input | 250 MHz | 250 MHz | 250 MHz | ||
Limit, selectable per channel | Off (250 MHz) 150 MHz 100 MHz 50 MHz | Off (250 MHz) 150 MHz 100 MHz 50 MHz | Off (250 MHz) 150 MHz 100 MHz 50 MHz | ||
AC coupling cut off frequency (-3dB) | ±1.5 Hz | ||||
SureConnect | Optionally available (option S) | ||||
Maximum voltage on connection | 200 V (DC + AC peak < 10 kHz) | ||||
Resistance measurement | Optionally available (option S) | ||||
Ranges (Full scale) | 100 Ω 200 Ω 500 Ω | 1 kΩ 2 kΩ 5 kΩ | 10 kΩ 20 kΩ 50 kΩ | 100 kΩ 200 kΩ 500 kΩ | 1 MΩ 2 MΩ |
Accuracy | 1 % of full scale | ||||
Response time (to 95%) | < 10 µs | ||||
Maximum sampling rate | HS6-1000 | HS6-500 | HS6-200 | ||
8 bit | |||||
measuring one channel | 1 GSa/s | 500 MSa/s | 200 MSa/s | ||
measuring two channels | 500 MSa/s | 200 MSa/s | 100 MSa/s | ||
measuring three or four channels | 200 MSa/s | 100 MSa/s | 50 MSa/s | ||
12 bit | |||||
measuring one channel | 500 MSa/s | 200 MSa/s | 100 MSa/s | ||
measuring two channels | 200 MSa/s | 100 MSa/s | 50 MSa/s | ||
measuring three or four channels | 100 MSa/s | 50 MSa/s | 20 MSa/s | ||
14 bit | 100 MSa/s | 50 MSa/s | 20 MSa/s | ||
16 bit | 6.25 MSa/s | 3.125 MSa/s | 1.25 MSa/s | ||
Maximum streaming rate 1 | HS6-1000 | HS6-500 | HS6-200 | ||
8 bit | |||||
measuring one channel | 200 MSa/s2 | 100 MSa/s2 | 40 MSa/s | ||
measuring two channels | 100 MSa/s3 | 50 MSa/s3 | 20 MSa/s | ||
measuring three or four channels | 50 MSa/s4 | 25 MSa/s4 | 10 MSa/s | ||
12 bit | |||||
measuring one channel | 100 MSa/s3 | 50 MSa/s3 | 20 MSa/s | ||
measuring two channels | 50 MSa/s4 | 25 MSa/s4 | 10 MSa/s | ||
measuring three or four channels | 25 MSa/s5 | 12.5 MSa/s5 | 5 MSa/s | ||
14 bit | |||||
measuring one channel | 100 MSa/s3 | 50 MSa/s3 | 20 MSa/s | ||
measuring two channels | 50 MSa/s4 | 25 MSa/s4 | 10 MSa/s | ||
measuring three or four channels | 25 MSa/s5 | 12.5 MSa/s5 | 5 MSa/s | ||
16 bit | 6.25 MSa/s6 | 3.125 MSa/s | 1.25 MSa/s | ||
Sampling clock source | |||||
Internal | TCXO | ||||
Accuracy | ± 0.0001 % | ||||
Stability | ± 1 ppm over 0°C to 55°C | ||||
Time base aging | ±1 ppm/year | ||||
External | LVDS, on CMI connectors | ||||
Input frequency | 10 MHz ± 1 % 16.369 MHz ± 1 % | ||||
Memory | Standard model | XM option | |||
8 bit resolution | |||||
Measuring one channel | 1 Mpts per channel | 256 Mpts per channel | |||
Measuring two channels | 512 Kpts per channel | 128 Mpts per channel | |||
Measuring three or four channels | 256 Kpts per channel | 64 Mpts per channel | |||
12, 14, 16 bit resolution | |||||
Measuring one channel | 512 Kpts per channel | 128 Mpts per channel | |||
Measuring two channels | 256 Kpts per channel | 64 Mpts per channel | |||
Measuring three or four channels | 128 Kpts per channel | 32 Mpts per channel | |||
Trigger | Only available in scope/block mode, not in streaming mode | ||||
System | Digital, 2 levels | ||||
Source | CH1, CH2, CH3, CH4, OR, digital external | ||||
Trigger modes | Rising edge, Falling edge, Any edge Inside window, Outside window, Enter window, Exit window (time conditions only on Ch1) Pulse width (only on Ch1) Interval (only on Ch1) | ||||
Level adjustment | 0 to 100 % of full scale | ||||
Hysteresis adjustment | 0 to 100 % of full scale | ||||
Resolution | 0.006 % (14, 16 bits) / 0.025% (12 bits) | ||||
Pre trigger | 0 to selected record length, 1 sample resolution | ||||
Post trigger | 0 to selected record length, 1 sample resolution | ||||
Trigger hold-off | 0 to 63 MSamples, 1 sample resolution | ||||
Trigger delay | 0 to 8 GSamples, 1 sample resolution | ||||
Digital external trigger | |||||
Input | Extension connector pins 1 and 2 | ||||
Range | 0 to 2.5 V (TTL) | ||||
Coupling | DC | ||||
Jitter | ≤ 1 sample | ||||
Multi-instrument synchronization | |||||
Using CMI | Synchronizing instruments via CMI is available when all instruments are connected via USB. | ||||
Maximum number of instruments | Limited by number of available USB ports | ||||
Synchronization accuracy | 0 ppm | ||||
CMI interface | 2x, CMI 1, CMI 2 | ||||
Required coupling cable | TP-C50H Coupling cable CMI | ||||
Maximum coupling cable length | 50 cm | ||||
Using WCMI | Synchronizing instruments via WCMI is available when instruments are connected via USB, LAN and WiFi. | ||||
Maximum number of instruments | No limitation | ||||
Required coupling module | WCMI - 8, WCMI - 9 | ||||
Clock synchronization accuracy | ≤ 1 ppm, typical ≤ 0.2 ppm | ||||
Trigger jitter at sample rate 1 | ≤ 1 MSa/s | > 1 MSa/s | |||
2 x "5" | ≤ ±2 samples | ≤ ±2 µs | |||
"5" and "6" | |||||
Trigger source "5" | ≤ ±2 samples | ≤ ±2 µs | |||
Trigger source "6" | ≤ ±8 samples | ≤ ±8 µs | |||
2 x "6" | ≤ ±8 samples | ≤ ±8 µs | |||
Probe calibration | |||||
Output | Extension connector pins 3 (signal) and 6 (ground) | ||||
Signal | Square wave | ||||
Level | -1 V to 1 V | ||||
Frequency | 1 kHz | ||||
Interface | |||||
Interface | USB 3.0 SuperSpeed (5 Gbit/s); (USB 2.0 HighSpeed compatible) | ||||
Power Requirements | |||||
Power | From USB port or external input | ||||
Consumption | 5 VDC 1200 mA max | ||||
External power | From second USB port or power adapter | ||||
Physical | |||||
Instrument | |||||
Height | 25 mm (1 inch) | ||||
Length | 170 mm (6.7 inch) | ||||
Width | 140 mm (5.2 inch) | ||||
Weight | 500 g (17.6 ounce) | ||||
USB cord length | 1.8 m (70 inch) | ||||
I/O connectors | |||||
Channel 1, 2, 3, 4 | BNC, female | ||||
USB | Fixed cable with USB 3.0 type A connector, 1.8 m | ||||
Extension connector | D-sub 9 pins female | ||||
Power | 3.5 mm power socket | ||||
CMI I/O connectors | 2 x HDMI type C socket | ||||
System requirements | |||||
PC I/O connection | USB 2.0, USB 3.0 or USB 3.1 | ||||
Operating system | Windows 10 / 11, 64 bits Linux (via libtiepie-hw SDK) | ||||
Environmental conditions | |||||
Operating | |||||
Ambient temperature | 20°C to 25°C (10°C to 40°C without specifications) | ||||
Relative humidity | 10 % to 90 %, non condensing | ||||
Storage | |||||
Ambient temperature | -20°C to 70°C | ||||
Relative humidity | 5 % to 95 %, non condensing | ||||
Certifications and Compliances | |||||
CE mark compliance | Yes | ||||
RoHS | Yes | ||||
EN 55011:2009/A1:2010 | Yes | ||||
EN 55022:2006/A1:2007 | Yes | ||||
EN 61000-6-1:2007 | Yes | ||||
EN 61000-6-3:2007 | Yes | ||||
Package contents | |||||
Instrument | Handyscope HS6 | ||||
Probes | 4 x Oscilloscope Probe 1:1-1:10 - HP-3250I | ||||
Accessories | Handyscope / WiFiScope power supply, external power cable for USB port, Probe compensation cable TP-DB9-BNC-30 | ||||
Software | for Windows 10 / 11, via website | ||||
Drivers | for Windows 10 / 11, via website | ||||
Software Development Kit | for Windows 10 / 11 and Linux, via website | ||||
Manuals | instrument manual and software user's manuals color printed and digital, via website | ||||
Optional Accessories | |||||
Optional accessories for the Handyscope HS6 need to be ordered separately | |||||
Measure lead single ended | Measure lead TP-BNCI-100 | ||||
Customer service | |||||
TiePie engineering instruments are designed, manufactured and tested to provide high reliability. In the unlikely event you experience difficulties, the TiePie engineering instruments are fully warranted for two years. | |||||
This warranty includes | All parts and labor (excluding probes and/or measure leads) No charge for return shipping Long-term 7 year support Upgrade to the latest software at no charge | ||||
Optionally available | Extension to five year warranty, option W5 |
The Handyscope HS6 is available in 3 different base models:
Order code | Max. sampling speed | Max. streaming speed |
---|---|---|
HS6-1000 | 1 GSa/s | 200 MSa/s |
HS6-500 | 500 MSa/s | 100 MSa/s |
HS6-200 | 200 MSa/s | 40 MSa/s |
Available options for the Handyscope HS6 are:
- XM: With the extended memory option, up to 256 Mpoints memory per channel is available. Without this option, the models have up to 1 Mpoints memory per channel.
- E: With the EMI option, the Handyscope HS6 is turned into a high accuracy EMI pre compliance tester. The EMI option includes the EMI probe set TP-EMI-HS6.
- S: With the SureConnect option, connection test and resistance measurement are available on all channels.
- W5: With the extended warranty option, warranty is five years on parts and labor. Without this option, the models have two years warranty on parts and labor.
The EMI option requires a Handyscope HS6 - 1000 in combination with at least option XM.
The Handyscope HS6 is delivered with:
Instrument | Handyscope HS6 |
---|---|
Oscilloscope probes | 4 x Oscilloscope Probe 1:1-1:10 - HP-3250I |
Accessories | Handyscope / WiFiScope power supply, external power cable for USB port, Probe compensation cable TP-DB9-BNC-30 |
Software | for Windows 10 / 11, via website |
Drivers | for Windows 10 / 11, via website |
Software Development Kit | for Windows 10 / 11 and Linux, via website |
Manuals | instrument manual and software user's manuals color printed and digital, via website |
Several downloads for the Handyscope HS6 are listed below, including Multi Channel oscilloscope software, drivers and manuals.
Driver & Software
Description | Version | Remarks | Size | |
---|---|---|---|---|
WinUSB driver | 10.0.2 | Windows 10 / 11, 64 bit | 1.73 MB | download |
Multi Channel software | 1.47.0 | Windows 10 / 11, 64 bit, including PDF manual | 103.76 MB | download |
Manuals & Documents
Description | Version | Remarks | Size | |
---|---|---|---|---|
Multi Channel software manual | 1.11 | English | 3.13 MB | download |
Handyscope HS6 Instrument manual | 2.49 | English | 650.00 kB | download |
Handyscope HS6 Data sheet | English | 4.74 MB | download |
Software Development Kit (SDK)
Interfacing the Handyscope HS6 with third party software and developing own software requires the libtiepie-hw Software Development Kit. Detailed information on the libtiepie-hw SDK, downloads for Windows and Linux platforms and bindings and programming examples for various programming environments can be found in the libtiepie-hw pages.