Oscilloscope probe SI-9002

Differential probe SI-9002

The Differential probe SI-9002 extends the measurement power of oscilloscopes to power semiconductor circuits. This Differential Probe provides any general oscilloscope with a high voltage differential input.

The Differential probe SI-9002 is small and light, so it can be used in a very convenient way; just plug it into the input of, for example, the Handyscope HS5. The wide bandwidth and the high accuracy of this Differential Probe cater for a wide range of applications.

Order code: SI-9002
EAN: 7423619693624
Price: 372.00

Category: Probes

Using a built-in differential amplifier, the Differential probe SI-9002 scales and converts the high voltage differential input to a low voltage single ended BNC output. The differential input is useful in measurements of power semiconductor circuits, as no reference to ground is required. Both the positive and negative sides of the balanced input possess high voltage differential input up to 700 V, and its sensitivity can extend down to 100 mV. With high bandwidth and high response speed, the Differential probe SI-9002 is adequate for accurate dV/dt measurement in the fastest switching circuits of thyristors, bipolar transistors, or power MOSFETS.

The table below shows detailed specifications of the Differential probe SI-9002.

Differential probe SI-9002 - Specification

BandwidthDC to 25MHz (-3dB)
Attenuation Ratio1/20 or 1/200
Accuracy±2%
Rise Time14 ns
Input Impedance4 MOhm
5.5 pF each side ground
Input Voltage
Differential Range 1
1/20±140 V (DC+Peak AC) or 140 Vrms
1/200±1400 V (DC+Peak AC) or 1000 Vrms
Common Mode Range±1400 V (DC+Peak AC) or 1000 Vrms
Absolute Max. Voltage 1±1400 V (DC+Peak AC) or 1000 Vrms CAT III
Output
Swing (into 2k ohm load)+/-7 V
Offset (typical)<+/-5 mV
Noise (typical)0.7 mVrms
Impedance (typical)50 Ohm (for using 1 MOhm input system oscilloscope)
CMRR (typical)-80 dB @ 50 Hz, -60 dB @ 20 kHz
Ambient
Operating Temperature-10 to 40 °C (14 to 104 F)
Storage Temperature-30 to 70 °C (-22 to 158 F)
Operating Humidity25 to 85% RH
Storage Humidity25 to 85% RH
Power RequirementsStandard 4 x AA cells
or regulated 9 VDC / 40mA mains adapter 2
Length of BNC Cable95 cm (37.4 inch)
Length of Input Leads45 cm (17.7 inch)
Weight (differential probe and PVC jacket)400 g (14.1 ounce)
Dimensions
Height21 mm (0.8 inch)
Length170 mm (6.7 inch)
Width63 mm (2.5 inch)
  1. Voltage limit is the lesser of the DC+Peak AC and RMS values.
    1. The supplied voltage must be less than 12V and greater than 4.4V, otherwise the differential probe could be damaged or can't be operated properly.
    2. Polarity is "+" inside and "-" outside. For wrong polarity, built-in circuit protects the differential probe, no danger or damage will occur.
    3. When the voltage of the cells become too low, the power indicator on the panel will flicker.
Information:

When using the Differential probe SI-9002 in combination with:

an extra grounding connection between the instrument and the Differential probe SI-9002 is required. When ordering a Differential probe SI-9002 to be used with one of these instruments, please mention that you also want the extra ground lead for the Differential probe SI-9002 and specify for which instrument.

Information:

When using the Differential probe SI-9002 in combination with

the used input channel of the scope must be set to single ended.

The Differential probe SI-9002 is delivered with:

AmountItem
1 Differential probe SI-9002
1 Protective rubber shell
1 Manual

DescriptionVersionRemarksSize
Differential probe SI-9002 ground lead manual1.0English217.12 kB download
Differential probe SI-9002 user manual1.1English101.69 kB download